Accessories

Everything needed for a complete installation according to standards

There are different reasons for installing a complete lightning protection system, but they could be reduced to two fundamentally:

  1. Having a lightning protection system is the best option to protect people, animals, structures, machinery, and facilities against this natural phenomenon.
  2. To comply with the regulations that regulate the installation of these systems.

At Aiditec Systems we have all the necessary accessories for the installation of these systems safely and in compliance with current regulations.

Spark gap
Vía de chíspas para tomas de tierra

Spark gap for equipotential protection for connection to lightning rods and grounding.

Reference Material Round conductors Flat conductors
AS500550 Stainless steel From Ø 8 to 10 mm Up to 30 mm
Complies with: IEC 62305 y EN 50164
Adaptation pieces

Adaptation piece for joining the lightning rod with the mast and internal connection with the down conductor.

Reference Material Mast For round For plate
AS700100 Stainless steel Ø 45 x 2 mm 2 x Ø 8/10 mm
Complies with: UNE 21186, NFC 17102 y NP 4426
Abarcón

U-Bolt for joining the lightning rod with the mast and with a stainless steel flange for the external connection with the down conductor.

Reference Material Mast For conductor For plate
AS700150 Stainless steel Up to Ø 45 mm Up to Ø 15 mm 50 x 5 mm
Complies with: UNE 21186, NFC 17102 y NP 4426
Mast
Mástil

Masts made of galvanized steel or stainless steel (optimal for highly corrosive environments) with a diameter of 45 and a thickness of 2 mm to be attached to buildings or structures with 2 supports (except 8 m masts that are fixed with 3 supports + guys).

Reference Material Sections / Length Total length (m)
AS700229 Galvanized steel 1 section / 2 m 2
AS700231 Galvanized steel 2 sections / 2 m 4
AS700233 Galvanized steel 3 sections / 2 m 6
AS700235 Galvanized steel 4 sections / 2 m 8
AS700270 Stainless steel 1 section / 2 m 2
AS700271 Stainless steel 2 sections / 2 m 4
AS700273 Stainless steel 3 sections / 2 m 6
AS700275 Stainless steel 4 sections / 2 m 8
Complies with: UNE 21186, NFC 17102 y NP 4426
Mástil autosoportado

Masts to be installed on a concrete block embedded in the ground, made of galvanized steel and studied to withstand winds of up to 140 km/h.

Reference Length Sections Assembly Base plate dimensions (mm) Foundation dimensions (cm)
AS700306 6 m 2 Screwed 400 x 400 x 10 80 x 80 x 80
AS700308 8 m 3 Screwed 400 x 400 x 10 80 x 80 x 80
AS700310 10 m 4 Screwed 500 x 500 x 10 100 x 100 x 100
AS700312 12 m 5 Screwed 500 x 500 x 10 100 x 100 x 100
AS700315 15 m 6 Screwed 500 x 500 x 10 150 x 150 x 150
AS700320 20 m 8 Welded 600 x 600 x 10 200 x 200 x 200
AS700325 25 m 10 Welded 750 x 750 x 12 200 x 200 x 200
Complies with: UNE 21186, NFC 17102 y NP 4426
Trestle towers

Trestle tower composed by upper section of the 180 series for masts up to 45mm in diameter + connectable sections with each other through thread + center pivot. 7 mm calibrated rod in discontinuous lattice. Are necessary 3 winds with 120o angle between them.

Reference Material Dimensions per section Weight per section
AS700355 Acero galvanizado 3000 x 20 x 1,5 mm 11 kg
Complies with: UNE 21186, NFC 17102 and NP 4426
Anchors
Anclajes de superficie

Anchors for fixing masts up to Ø 45 mm to roofs and flat surfaces.

Reference Material Tube height Base plate dimensions
AS700400 Galvanized steel 75 cm 300 x 300 mm
AS700401 Galvanized steel 100 cm 500 x 500 mm
AS700602 Zinc plated steel 45 cm 250 x 250 mm
AS700603 Zinc plated steel 75 cm 250 x 250 mm
Complies with: UNE 21186, NFC 17102 y NP 4426
Anclaje para empotrar o atornillar

Standard anchor to embed or screw. Manufactured in a «U» profile of 20 x 40 x 20 and thickness of 3 mm.

Reference Material Length Type of fixing
AS700624 Galvanized steel 20 cm To screw
AS700625 Galvanized steel 35 cm To screw
AS700626 Stainless steel 50 cm To screw
Complies with: UNE 21186, NFC 17102 y NP 4426
Anclaje ligero para empotrar

Light anchor to embed. Manufactured in a «U» profile.

Reference Material Length
AS700440 Galvanized steel 35 cm
AS700441 Galvanized steel 50 cm
AS700640 Stainless steel 35 cm
AS700641 Stainless steel 50 cm
Complies with: UNE 21186, NFC 17102 y NP 4426
Anclaje para fijación paralela y en cruz

Anchors for parallel and cross fixing of masts up to Ø 45 mm.

Reference Material Length Type of fixing
AS700460 Galvanized steel 20 cm Parallel
AS700481 Galvanized steel 20 cm +
AS700660 Zinc plated steel 20 cm Parallel
AS700681 Zinc plated steel 20 cm +
Complies with: UNE 21186, NFC 17102 y NP 4426
Anclaje para soldar

Anchor for welding to structures. Manufactured in a «U» profile of 20 x 40 x 20 mm and thickness of 3 mm.

Reference Material Length
AS700500 Galvanized steel 35 cm
AS700501 Galvanized steel 50 cm
AS700700 Zinc plated steel 35 cm
AS700701 Zinc plated steel 50 cm
Cumple con: UNE 21186, NFC 17102 y NP 4426
Anclaje regulable

Adjustable anchor made of a 20 x 40 x 20 mm «U» profile and 3 mm thick. Fixation by screws.

Reference Material Regulation
AS700540 Galvanized steel From 50 to 80 cm
Complies with: UNE 21186, NFC 17102 y NP 4426
Anclaje para torreta

Anchors for fixing masts to turrets and lattices. Manufactured in a «U» profile of 20 x 40 and 3 mm thick.

Reference Material Length For turrets
AS700560 Galvanized steel 42 cm Model 180
AS700561 Galvanized steel 49 cm Model 250
AS700562 Galvanized steel 60 cm Model 360
AS700760 Zinc plated steel 42 cm Model 180
AS700761 Zinc plated steel 49 cm Model 250
AS700762 Zinc plated steel 60 cm Model 360
Complies with: UNE 21186, NFC 17102 y NP 4426
Conductors
Pletina de acero inoxidable

Bare flat conductors are recommended by lightning protection regulations as downstream and ground conductors.

Reference Material Dimensions
AS600121 Tinned copper 30 x 2 mm
AS600181 Stainless steel 30 x 2 mm
Complies with: IEC 62305, EN 50164, EN 13601, BS 7430, UNE 21186, NFC 17102, NP 4426, AS 1567, BS 6746, BS 2898, BS 6360 and AS 1866
Conductor macizo

Bare solid conductors are recommended by lightning protection regulations for use in highly corrosive environments.

Reference Material Dimensions
AS600200 Copper Ø 8 mm
AS600260 Galvanized steel Ø 8 mm
AS600261 Galvanized steel Ø 10 mm
Complies with: IEC 62305, EN 50164, EN 13601, BS 7430, UNE 21186, NFC 17102, NP 4426, AS 1567, BS 6746, BS 2898, BS 6360 and AS 1866
Conductor trenzado

Bare stranded conductors are recommended by lightning protection regulations for use in highly corrosive environments.

Reference Material Dimensions Wires
AS600301 Copper 50 mm2 19
AS600302 Copper 75 mm2 19
AS600303 Copper 95 mm2 19
Complies with: IEC 62305, EN 50164, EN 13601, BS 7430, UNE 21186, NFC 17102, NP 4426, AS 1567, BS 6746, BS 2898, BS 6360 and AS 1866
Fixings for conductors

Clamps for fixing flat conductors to buildings and structures. Includes plug and screw.

Reference Material For conductor Conductor elevation
AS600460 Stainless steel Up to 30 mm wide 10 mm
AS600461 Stainless steel Up to 30 mm wide 60 mm with extension
AS600462 Stainless steel Up to 30 mm wide 110 mm with extension
AS600481 Nylon Up to 30 mm wide 25 mm
AS600482 Nylon Up to 30 mm wide 40 mm
AS600450 Stainless steel 30 x 2 Without extension
Complies with: UNE 21186, NFC 17102 and NP 4426

Staples for fixing round conductors to buildings and structures. Includes plug and screw.

Reference Material For conductor Conductor elevation
AS600560 Nylon Ø 7 to 10 mm 10 mm
AS600561 Nylon Ø 7 to 10 mm 60 mm with extension
AS600562 Nylon Ø 7 to 10 mm 110 mm with extension
AS600580 Nylon Ø 7 to 10 mm 25 mm
AS600581 Nylon Ø 7 to 10 mm 40 mm
Complies with: UNE 21186, NFC 17102 and NP 4426

Conical support for fixing conductors to flat surfaces.

Reference Material For round conductor For flat conductor
AS600600 Polypropylene Ø 6-11 mm 30 x 4 mm
Complies with: UNE 21186, NFC 17102 and NP 4426
Separador para fijación de conductores

Spacers/extensions for fixing conductors to buildings and structures.

Reference Material Diameter Length
AS600680 Stainless steel Ø 25 mm 50 mm
AS600681 Stainless steel Ø 25 mm 100 mm
AS600690 Brass Ø 25 mm 50 mm
AS600691 Nylon Ø 25 mm 100 mm
Complies with: UNE 21186, NFC 17102 and NP 4426
Supports for conductor fixation

Supports for fixing conductors to flat surfaces.

Reference Material Support For conductor Status
AS600600 Polypropylene Conical Ø 8 mm Empty
AS600601 Polypropylene Conical Ø 8 mm Filled
AS600620 Concrete Block Ø 8 mm
Complies with: UNE 21186, NFC 17102 and NP 4426

Supports for fixing conductors to tiles.

Reference Material For conductor Type
AS600640 Stainless steel From Ø 6 to 11 mm Adjustable 170/240 mm
AS600641 Stainless steel To Ø 8 mm Extensible 170/280 mm
AS600642 Stainless steel From Ø 6 to 10 mm Adjustable 120/240 mm (for ridge cap)
AS600643 Copper From Ø 6 to 10 mm Adjustable 120/240 mm (for ridge cap)
AS600660 Stainless steel To Ø 8 mm Pressure. For 8/10 mm thickness
AS600661 Stainless steel To Ø 8 mm Pressure. For 15/20 mm thickness
AS600670 Stainless steel From Ø 6 to 10 mm For sandwich type roofs
AS600700 Stainless steel Not include fixing For pipes from Ø 60 to 150 mm
AS600720 Stainless steel Not include fixing For pipes from Ø 60 to 150 mm
AS600740 Copper Not include fixing For pipes from Ø 60 to 150 mm
Complies with: EN 50164, UNE 21186, NFC 17102 and NP 4426
Soporte para fleje de acero inoxidable

Support for stainless steel strip

Reference Material Screw For conductor Tensioning strap
AS600750 Stainless steel M8 – 10 mm Ø 8 mm 15 x 0,4 mm
Complies with: UNE 21186, NFC 17102 and IEC 62305
Joints and connections
Borna multiclamp

Universal connector for round stainless steel conductors with multiple connection methods.

Reference Material Dimensions For conductor Screw
AS600841 Stainless 40 x 40 x 40 mm For Ø 8 to 10 mm M-10 x 40 mm
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426
Seccionador

Cross connector for flat and round conductors and test link.

Reference Material For conductor For flat For electrode
AS600823 Stainless steel Up to Ø 10 mm Up to 30 x 3 mm Up to Ø 17 mm
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426
Conector en T para conductores redondos

T-connector for round conductors.

Reference Material For conductor
AS600806 Copper From Ø 8 to 10 mm
AS600845 Galvanized steel From Ø 8 to 10 mm
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426
Conector lineal para conductores redondos

Linear connector for round conductors.

Reference Material For conductor
AS600804 Copper Up to Ø 10 mm
AS600824 Stainless steel Up to Ø 10 mm
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426
Conector paralelo para conductores redondos

Parallel connector for round conductors.

Reference Material For conductor
AS600844 Copper From Ø 7 to 10 mm
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426
Conector a canalón

Gutter connector for round conductors.

Reference Material For conductor
AS600821 Stainless steel From Ø 6 to 10 mm
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426
Conector bimetálico

Bimetallic connector with an intermediate plate for flat and round conductors.

Reference Material For conductor For flat
AS600870 Cu / Fe From Ø 8 to 10 mm
AS600871 Cu / Fe From Ø 8 to 10 mm Up to 30 mm
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426

KS type connector for round conductors.

Reference Material For conductor
AS600847 Brass From Ø 6 to 10 mm
AS600826 Brass From Ø 6 to 10 mm
AS600808 Brass From Ø 6 to 10 mm
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426
Other accessories
Tubo de protección

Tube for the mechanical protection of the down conductor of the protection system.

Reference Material Length For conductor For flat
AS600950 Galvanized steel 2 m Up to Ø 15 mm Up to 30 mm
AS600951 Stainless steel 2 m Up to Ø 15 mm Up to 30 mm
AS600952 Cross-linked polyethylene 2 m Up to Ø 15 mm Up to 30 mm
Complies with: IEC 62305, EN 50164, UNE 21186, NFC 17102 and NP 4426
Protector de lluvia

Rain protector to prevent the passage of water on roofs or flat surfaces where spikes or masts are embedded.

Reference Material Dimensions For spikes or masts
AS600965 Neoprene 115 x 115 x 60 mm Up to Ø 50 mm
Complies with: UNE 21186, NFC 17102 and NP 4426
Kit de vientos

Fastening and tensioning of masts by means of steel winds to prevent falls due to the effect of the wind.

Reference Material Cable section Length
AS700352 Stainless steel Ø 3 mm 50 m
Complies with: UNE 21186, NFC 17102 and NP 4426
Cable aislante

Non-flammable insulated cable to ensure systems work in extreme conditions.

Reference Material Section Type of coating
AS600306 Copper 50 mm2 Flame retardant
Complies with: UNE 21186, NFC 17102 and NP 4426
Tubo zapa

Flexible metal tube for cable protection.

Reference Material Section Type of coating
AS600752 Steel Ø 16 mm PVC
Complies with: UNE 21186, NFC 17102 and NP 4426

Sectionalizing box for testing grounding resistance.

Reference Material Dimensions Type of coating
AS600401 Polycarbonate + ABS 95 x 145 x 75 mm Copper
Complies with: UNE 21186, NFC 17102 and NP 4426
Tubo multicapa

Cross-linked polyethylene protection tube against metallic shocks.

Reference Material Diameter Section Length Weight
AS600951 Crosslinked polyethylene 3 mm Ø 8 – 10 mm 50 – 70 mm2 2000 mm 728 gr.
AS600960 Crosslinked polyethylene 3 mm Ø 8 – 10 mm 50 – 70 mm2 2500 mm 910 gr.
Complies with: UNE 21186, NFC 17102 and NP 4426
NOTE
If you need an accessory with different characteristics, contact us and our technical department will advise you on the most appropriate choice.

How can we help you?